Arm the System:
With all the Terminals, (Strips & Splitters), and
Sensors attached:
Check to see there are no flashing
LED Lights on Sensors.
Check to see there are no Lights lit on
the Bar Graphs.
If no lights are lit, proceed to step 17.
If lights are still lit, proceed to steps 19 & 20.
17
. Arm the system by entering your 4-digit
code, or the factory preset code of: [*]1-2-3-4.
(Keyed Units: Turn the key clockwise & remove).
Disarm the System:
18. Disarm the system by entering your 4-digit
code, or the factory preset code of: [*]1-2-3-4.
(Keyed Units: Turn the key counterclockwise). If
a sensor was detached, the horn will stop beep-
ing; the Bar Graphs will light showing the 1st
location of a tampered sensor, and the battery
light will stop moving at the point the system was
disarmed.
When an Alarm Occurs:
If any part of the system is disturbed, the ME
Alarm System will give both visual & audible
alerts. The horn will )))SOUND(((, the LED Light
on affected sensor(s) will FLASH. . . red, green,
red. . . and the LED light on the Terminal , (Strip
or Splitter) will FLASH green. In addition, the
Bar Graphs on the ME Control Panel will light-up
showing the 1st location of one or more
detached sensors.
19. Determine the location of the 1st Sensor
Alarm by checking the Bar Graphs. You will
see which terminal and sensor in the chain is
affected. We strongly recommend that you reac-
tivate the sensor by removing it from the product,
and reapplying it, (see steps 9 through 13).
Press and hold the RESET Button until the next
affected sensor is indicated on the Bar Graph.
The light on the 1st detached sensor will turn
from GREEN to RED.
20. The Bar Graph shows the next affected
sensor; follow the same procedure to reactivate
the sensor connected to each product. Press
the RESET Button after each reactivated con-
nection to clear that alarm.
When you press the RESET Button to clear
each alarm, the horn will )))SOUND(((, and the
sensor’s LED LIght will turn from GREEN to
RED.
Rearm the System:
21. When all Sensor Bar/Lights and Terminal
lights are OUT, you may rearm the system. Arm
the system by entering your 4-digit code, or the
factory preset code of: [*] 1 - 2 - 3- 4.
(Keyed Units: Turn the key clockwise & remove).
Special Reset:
If someone forgot to disarm the system before
removing a Strip, Splitter or Sensor, the alarm
)))SOUNDS((( and the Bar Graph will indicate
the location of the event.
22
. Disarm the system, reconnect the break, or
rework the display. (Remember that an ME
Terminal End Plug MUST
BE placed in the last
outlet of the last terminal, and no where else in
the system). Press and hold the TEST Button
until the horn sounds. This reconfigures the sys-
tem. You can now rearm the system without
reactivating any sensors. We recommend that
you review the cause of the alarm conditions
before using the Special Reset.
Low Battery Warning:
When the battery falls below recommended lev-
els, the Battery Bar Graph lights stop, and the
horn will “Double Beep” 7 to 10 seconds.
23. Unlock and remove the screw on the side of
the alarm module to open the battery compart-
ment with a Phillips Head screw driver as shown
in Fig. 1 on page 2.
24. Replace the (6) “C” cell (alkaline) batteries
loading them into the battery tubes with the (+ -)
polarity as indicated.
25. Replace the battery cover.