Install Terminals:
When the power is first applied to the (SK-210KME) Keypad Alarm System, the keypad
uses the factory pre-set code: 1-2-3-4.
6. To deactivate Keypad Alarm Systems: Enter the factory pre-set code: [*] 1-2-3-4.
To deactivate Keyed Alarm Systems: Insert the key and turn counterclockwise.
(NOTE: The unit will BEEP every 30 seconds to indicate the unit is disarmed).
7. Plug the 1st (Splitter or Strip) into the back of the alarm module as shown in Fig. 2 above.
The ME Senior III is designed to work with up to 12 terminals, (Splitters or Strips) each with a
capacity of up to 12 sensors to protect a maximum of 144 products. You can use any combination of
ME Splitters or Strips, (up to a maximum of 12), daisy-chained together, as shown in Fig. 3 above.
8. After the 1st Splitter or Strip is plugged into an ME Alarm Module, additional
Splitters or Strips can be daisy-chained together. Remove (and save) the
(SK-209ME) Terminal End Plug that is plugged in at the end of each terminal,
and plug the next ME Splitter or Strip in there.
(NOTE: The ME End Plug MUST
BE placed in the last outlet of the last terminal).
Installing “LE” Sensors:
The ME Alarm System utilizes the Se-Kure Controls complete line of “LE” Sensors.
Sensors are available to adhere, lasso, and tie-wrap to display products. If you require additional
assistance finding the right sensor(s) to accommodate your specific needs, your knowledgeable
Customer Service Representative is available to help you.
Calculators
Power
Tools
Computers
Lap Tops
Boom Boxes
12 Port Strip
6 Port Strip
6 Port Splitter
Portable CD
Players
Phones
Fig.
3
Page 2
SK-904PC/LE
6’ (Coiled) Rectangular Sensor
Phone Connector
(Plugs into an ME Splitter or Strip)
Cable
(Available in Straight or Coil)
Sensor
(Adheres to Display Product)
SK-209ME
ME Terminal End Plug
Battery Installation:
3. Insert and turn the key, then remove the Phillips Head
Screw on the side of the alarm module to open the battery
compartment as shown in the Fig. 2 at right.
4. Insert (6) “C” cell (alkaline) batteries into the battery
tubes with the (+ -) polarity as indicated.
5. Replace the battery cover plate and the screw.
Note: If the security screw is loose, or removed, when
armed, the alarm will (((sound))).
Fig. 2
IMPORTANT! Make sure the AC/DC Power Supply is
plugged in before installing batteries.